Sepsis Screen Parameters in Blood Culture Positive Neonatal Sepsis

Authors

  • Vijay Kumar Sah Department of Pediatrics and Neonatology, Nobel Medical College and Teaching Hospital, Biratnagar, Nepal
  • Sunil Kumar Yadav Department of Pediatrics and Neonatology, Nobel Medical College and Teaching Hospital, Biratnagar, Nepal
  • Arun Giri Department of Pediatrics and Neonatology, Nobel Medical College and Teaching Hospital, Biratnagar, Nepal
  • Sandip Kumar Singh Department of Pediatrics and Neonatology, Nobel Medical College and Teaching Hospital, Biratnagar, Nepal

DOI:

https://doi.org/10.3126/jonmc.v11i2.50454

Keywords:

Blood culture, Neonate, Sepsis

Abstract

Background: Neonatal sepsis is a clinical syndrome of bacteremia characterized by systemic signs and symptoms of infection in the first 28 days of life. Although, Positive blood culture is the gold standard for the diagnosis of neonatal septicemia, definitive culture results take at least 48–72 h, resulting in treatment delay. Hence certain rapid diagnostic tests such as C-reactive protein, micro erythrocyte sedimentation rate, total white blood cell count, absolute neutrophil count, and immature/total neutrophil count ratio collectively termed as the “Sepsis Screen” is used. The aim of this research is to study the relation between sepsis screen parameters and blood culture proven neonatal sepsis and to assess the clinical profile of neonates with culture-proven sepsis.

Materials and Methods: This was a descriptive observational study conducted on 97 clinically suspected neonatal sepsis cases in the neonatal intensive care unit.. Sepsis screen tests were evaluated for sensitivity, specificity, positive predictive value and negative predictive value. The culture results were correlated with sepsis screen tests and p-value<0.05 was considered significant. 

Results: Early-onset sepsis was seen in 47.4% cases, while late-onset sepsis accounted for 52.6% cases. Immature to total neutrophil ratio was the single best reliable sepsis screen test with a high specificity, PPV, and negative predictive values of 93.8%, 85.7%, and 88.4% respectively.

Conclusion: Most of the individual sepsis screen parameters showed statistical correlation with blood culture status, yet Immature to total neutrophil ratio had highest sensitivity, specificity, positive predictive value and proved to be a sensitive and responsive indicator of neonatal sepsis.

Downloads

Download data is not yet available.
Abstract
38
PDF
54

Author Biography

Vijay Kumar Sah, Department of Pediatrics and Neonatology, Nobel Medical College and Teaching Hospital, Biratnagar, Nepal

Associate Professor

Downloads

Published

2022-12-31

How to Cite

Sah, . V. K., Yadav, S. K., Giri, A., & Singh, S. K. (2022). Sepsis Screen Parameters in Blood Culture Positive Neonatal Sepsis. Journal of Nobel Medical College, 11(2), 48–51. https://doi.org/10.3126/jonmc.v11i2.50454

Issue

Section

Original Articles