Comparison of endotracheal tube cuff inflation techniques by stethoscope and “just seal” method in patients undergoing surgeries under general anesthesia

Authors

  • Mona Rajbhandari National Academy of Medical Sciences Bir Hospital, Kanti Path, Kathmandu 44600, Nepal https://orcid.org/0000-0003-3798-881X
  • Nagendra Bahadur KC Nepalese Army Institute of Health Sciences, Bhandarkhal, Syanobharyang, Kathmandu 44600, Nepal
  • Bhuban Raj Kunwar Nepalese Army Institute of Health Sciences, Bhandarkhal, Syanobharyang, Kathmandu 44600, Nepal
  • Bindu Laxmi Shah National Academy of Medical Sciences Bir Hospital, Kanti Path, Kathmandu 44600, Nepal

DOI:

https://doi.org/10.3126/jsan.v5i1.23213

Keywords:

Cough, endotracheal intubation, sore throat

Abstract

Background: Overinflation of the endotracheal tube cuff affects tracheal mucosa blood supply that causes postoperative complications like cough, sore throat and hoarseness. There is no standard cuff inflation technique that produces appropriate cuff pressure. The aim of this study was to find out better technique of cuff inflation that will produce adequate pressure with limited complication using stethoscope guided and “just seal”.

Methods: This was prospective, randomized single blinded study of 100 American Society of Anesthesiologists Physical Status (ASA PS) I and II patients of 18-65 years undergoing elective surgery under general anesthesia requiring endotracheal intubation. Group J (n=50) received ‘just seal’ method of tracheal cuff inflation where air was introduced into cuff until audible leak at mouth disappeared and Group S (n=50) received stethoscope-guided tracheal cuff inflation where air was introduced into cuff until harsh breath sound changed to soft while listening with stethoscope bell over the thyroid cartilage. Volume of air in endotracheal tube cuff, cuff pressure following inflation and post-operative sore throat, hoarseness and cough at 24 hour were assessed.

Results: Demographic details, mean volume of air in cuff, mean cuff pressure and incidence of postoperative adverse effects like sore throat, hoarseness and cough at 24 hours between the groups were comparable.

Conclusion: Both the stethoscope guided and “just seal” cuff inflation techniques were equally effective in producing adequate cuff pressure of 20-30 cmH2O with limited complication.

Downloads

Download data is not yet available.
Abstract
430
PDF
409

Author Biography

Mona Rajbhandari, National Academy of Medical Sciences Bir Hospital, Kanti Path, Kathmandu 44600, Nepal

Department of Anesthesiology

Downloads

Published

2019-03-15

How to Cite

Rajbhandari, M., KC, N. B., Kunwar, B. R., & Shah, B. L. (2019). Comparison of endotracheal tube cuff inflation techniques by stethoscope and “just seal” method in patients undergoing surgeries under general anesthesia. Journal of Society of Anesthesiologists of Nepal, 5(1), 16–21. https://doi.org/10.3126/jsan.v5i1.23213

Issue

Section

Original Articles